Troubleshooting the alarm when PM2.5 mass concentration is stuck to zero

How to diagnose and resolve issues causing PM2.5 mass concentration measurements being stuck to zero.

The alarm is raised when 100% of the raw PM2.5 mass concentration readings acquired in the last 24-hour period are reporting zero µg/m3. The presence of this alarm might indicate a fan or laser diode malfunction.

Note: if a Calibration is applied to the Node, you might see values different from zero on Dashboard charts when this alarm is triggered. Use Dashboard controls to to view raw data if you want to verify the problem.

 

To troubleshoot the Node, please perform the following steps:


  • Ensure the Node is properly deployed outdoors and exposed to ambient PM2.5 levels.

    • Constant zero readings are rare but possible. If the Node is in an area with exceptionally clean air, try moving it to a different location to check for a false alarm.
  • Power cycle the Node:

    • Unplug and replug the solar panel or power adapter.
    • After the Connection Successful sound, listen for a faint fan noise by placing your ear near the Node's air inlet or outlet (black knobs at the bottom). Do this in a quiet environment.
  • If you don't hear the fan:

    • The fan may be stuck due to debris. Follow these steps to clear any blockage.
  • If the raw PM2.5 Mass Concentration remains at zero after these steps, please contact our Support team Support team for a replacement.